Sign In | Join Free | My burrillandco.com
Home > Dimmable Motion Sensor >

1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height

Shenzhen Merrytek Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height from wholesalers
     
    Buy cheap 1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height from wholesalers
    • Buy cheap 1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height from wholesalers
    • Buy cheap 1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height from wholesalers
    • Buy cheap 1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height from wholesalers
    • Buy cheap 1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height from wholesalers
    • Buy cheap 1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height from wholesalers

    1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height

    Ask Lasest Price
    Brand Name : Merrytek
    Model Number : MC049V R
    Certification : CE, RED,TUV
    Price : Negotiation
    Payment Terms : T/T or western Union
    Supply Ability : 20,000pcs per month
    Delivery Time : 1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit.
    • Product Details
    • Company Profile

    1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height

    1-10V Dimmable Microwave Motion Sensor For Tri-proof Light, 6m Max Mounting Height, With Sync ON/OFF Function


    1. Features


    • Standard product, with 1-10V LED dimming drive, achieve 2-step or 3 step dimming function with 1-10V dimmable led driver,with a synchronous end
    • Detection area,hold time,daylight sensor,stand-by period,dim level by DIP switch
    • Convenient connection for user by pressed terminals for input and output end

    2. Parameters


    InputOperating voltage108-305V AC 50Hz/60Hz
    Rated voltage120-277V AC
    Stand-by power≤0.5W(230Vac)
    OutputWorking modeON/OFF 1-10V dimming
    Type of loadWhite woven light/power supply /1-10V LED light
    Load capacity

    120Vac 400W(inductive or resistive)

    220Vac-240Vac 800W(inductive or resistive)

    277Vac 1000W(inductive or resistive)

    Max.surge capacity30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start); 60A (50% Ipeak, twidth =200uS, 230Vac, full load, cold start)
    Dim interface1-10V DimmingAvailable
    Syn controlAvailable(Can sync for on-off function,can’t sync for 1-10V dimming )
    Sensor parametersOperating frequency5.8 GHz ±75 MHz,ISM band
    Transmitting power1mW Max.
    Detection Area25%/50%/75%/100%(by two DIP switches)
    Hold time5s/30s/90s/3min/20min/30min(by three DIP switches)
    Stand-by dim Level10%(1.4-1.6V)/20%(1.9-2.1V)/30%(2.9-3.1V)/50%(4.9-5.1V)(by two DIP switches)
    Stand-by Period0S/5S/5min/10min/30min/1h/+∞(by three DIP switches)
    Daylight Sensor2 lux/5Lux /10Lux /25Lux /50Lux /100Lux /Disable(by four DIP switches)

    Detection Range

    (100% Sensibility Radius)

    Surface mounting 3m height:0.3m/S ≥3.5m,1m/S ≥2.5m

    Horizontal mounting 2m height:0.3m/S ≥8m,1m/S ≥4m

    Mounting height3m(6m max)

    3db beam Angle


    80°@XZ plane

    96°@YZ plane

    Operating envrionmentOperating Temperature-25℃~70℃
    Storage Temperature/humidity-40℃~80℃ humidity:≤85% (non-condensation)
    Certificate StandardsSafety(LVD) standardsEN61058-1,EN61058-1-2,
    lightning surge1KV(L/N,EN61000-4-5)
    EMC standards

    EN61058-1,EN61000-3-2,EN61000-3-3,EN62479,

    EN301489-1,EN55015,EN300440

    Environmental RequirementCompliant to RoHS
    CertificateCE, RED,TUV
    OthersInput/Output(connector/wiring)specificationPress-in terminals wire diamter:0.75-1.5mm2
    Installation RequirementBuilt-in
    Installation Dimension180*50*30mm
    Package RequirementBubble bag+ Clapboard+ Carton(K=A)
    Net weight75g
    Life time5 years warranty @Ta 230V full load

    3. Parameters


    1. On-off function(Stand-by Period “0s”)


    2. 2-step dimming function(Stand-by Period“+∞”)



    3. 3-step dimming function(Stand-by Period“5s/5min/10min/30min/1h”)



    4. Dimension (mm)


    5. Wiring
    6. Structure
    7. Structure
    1. Detection Area
    12
    ONON100%
    ON-75%
    -ON50%
    --10%
    2. Hold Time
    345
    ONONON5S
    -ONON30s
    ON-ON90S
    --ON3min
    ONON-20min
    ---+∞

    3. Stand-by Period


    678
    ONONON0S
    -ONON5S
    ON-ON5min
    --ON10min
    ONON-30min
    -ON-1H
    VII---+∞

    4. Daylight Sensor


    1234
    --ONON2Lux
    ---ON5Lux
    -ONON-10Lux
    --ON-25lux
    -ON--50lux
    ON---100lux
    VII----Disable

    * When set to Disable, the sensor will turn on the light when it detects movement, regardless of whether the light is sufficient.

    * Daylight threshold value is the typical value under the condition of sunny environment, no shading, diffuse reflection of ambient light.


    5. 1-10V(Stand-by DIM Level)


    56Brightness%
    ONON50%
    -ON30%
    ON-20%

    -

    -10%
    8. Initialization
    After power on, the sensor automatically turns on light at 100% brightness. After 10 seconds, it turns off the light. During the initialization, the sensor is not able to detect movement
    9. Factory setting
    Detection area: 100%, Hold time: 5s, Stand-by Period: 0s, Daylight Sensor: Disable
    10. Application notice

    1) The sensor should be installed by a professional electrician. Please turn off the power before installing, wiring, changing the setting of the DIP switch.

    2) Microwave cannot penetrate metal, please avoid installing the product in closed or semi-closed metal lamps, and ensure that there is no metal or glass shield above the product; If the antenna must pass through the metal plate, ensure that the top of the sensor is close to the metal plate.

    3) The installation distance between microwave sensors is recommended to be greater than 3m, and should be far away from switches, routers and other wireless devices to avoid radio interference. The installation distance between both is recommended to be greater than 2m; The antenna surface of the microwave sensor must be far away from the input AC and output DC to avoid interference from low/high frequency signals.

    4) Long-term vibration equipment or moving objects should be avoided around the microwave sensor. The vibration signal generated will be regarded as mobile signal triggering induction. If a pet passes by in the test area, the sensor may be triggered.

    5)This product is suitable for indoor installation,if for semi-outdoor or outdoor installation, wind and rain may be regarded as a mobile signal trigger induction; When the sensor is installed in a metal lamp, metal reflective surface, or a narrow enclosed environment, the microwave will be reflected repeatedly and cause false triggering. Please reduce the sensitivity or contact the manufacturer for technical support.

    6)This model is suitable for ceiling installation. If wall installation is used, the microwave induction detection distance will be greatly increased, which may lead to microwave penetration through the wall or the lamp will not be off. Please adjust the sensitivity by 25%. If 25% cannot be used, avoid wall installation or contact the manufacturer for technical support.

    7)Product specifications and parameters may be optimized without prior notice.

    8) The light sensitivity threshold is in a sunny environment, no shadow and ambient light diffuse reflection.Lux level detected by sensor could be different in different period and climate condition.

    9) Product detection range is related to the moving speed of the object, the size of the object, the installation height of the product, the installation angle, the installation environment, the material of the reflection and other factors.

    10) The detection distances given in the specifications are typical values, which are obtained by testers in an indoor open environment of 165cm/65kg.

    11) Do not put the sensor near high-density objects, such as metal, glass, mixed walls, etc., because the sensor may trigger incorrectly.

    12) Sensor parameters may need to be reconfigured in different installation environments. Please refer to the above instructions or contact the manufacturer.